Skip to content
Manual / KWP2000 Timings, Services & Security Access

5.7. KWP2000 Protocol Timings & Fast Initialization across ME7.5 Clusters#

All Bosch ME7.5 engine control units utilize the ISO 14230-4 / KWP2000 (Keyword Protocol 2000) standard over a single bi-directional diagnostic line (Pin 43 / K-Line) conforming to ISO 9141-2 physical transceivers. When establishing communication for calibration extraction, datalogging, or high-speed reflashing, diagnostic tools must strictly observe the initialization sequence and inter-byte bus timings.

1. Fast Initialization Sequence (Fast Init)#

Standard 5-baud initialization is deprecated on ME7.5 in favor of the Fast Initialization sequence:

  1. Line Idle: The tester holds the K-Line at passive pull-up (12\text{V}) for at least 300\text{ ms} (T_{\text{idle}}).
    • Key Bytes: 0xEA and 0x8F designate standard Keyword 2000 with physical addressing and normal timing parameters.
  2. Wakeup Low Pulse (T_{\text{iniL}}): The tester pulls the K-Line low (0\text{V}) for exactly 25.0\text{ ms} \pm 1.0\text{ ms}.
  3. Line Recovery High Pulse (T_{\text{wup}}): The tester releases the K-Line high for 25.0\text{ ms} \pm 1.0\text{ ms}.
  4. Tester Start Communication Request (Service $81): The tester transmits the 4-byte KWP2000 initialization telegram at 10,400\text{ bps} (8\text{N}1): \mathbf{\text{Telegram: } [0\text{x}81, \ 0\text{x}11, \ 0\text{x}F1, \ 0\text{x}81, \ 0\text{x}04]}
  5. ECU Positive Response (Service $C1): Within 20\text{ ms} to 50\text{ ms}, the ECU returns: \mathbf{[0\text{x}83, \ 0\text{x}F1, \ 0\text{x}11, \ 0\text{xC1}, \ 0\text{xEA}, \ 0\text{x8F}, \ 0\text{x7F}]}
2. KWP2000 Inter-Byte & Inter-Message Timing Limits#

BOSCH ME7.5 KWP2000 BUS TIMING SPECIFICATION

TimingDescriptionMinimumMaximumDefault Value
P1Inter-byte time for ECU response0 ms20 ms0 ms
P2Time between Tester request & ECU reply25 ms50 ms25 ms
P3Time between ECU reply & next request55 ms5000 ms55 ms
P4Inter-byte time for Tester request0 ms20 ms0 ms
3. High-Speed Baud Rate Negotiation#

While standard diagnostics operate at 10,400\text{ bps}, ME7.5 bootloaders support dynamic baud rate escalation via Service $87 (AccessTimingParameters) or Bosch proprietary switching sequences:

  • 38,400\text{ bps}: Maximum reliable rate across noisy vehicle wiring or unshielded OBD cables.
  • 57,600\text{ bps}: Standard high-speed bench flashing rate.
  • 125,000\text{ bps}: Maximum hardware rate supported by the internal C167CR Asynchronous Serial Channel 0 (ASC0) using a 20\text{ MHz} CPU crystal.

← Back to contents